Multi-line 2 AGC 150 Application Software

您即将下载 Multi-line 2 AGC 150 Application Software

您已选择下载我们的软件。

几秒钟内,您将收到一封包含下载链接的电子邮件。

如果使用软件有问题,请联系support@deif.cn.

诚挚的祝福,

DEIF A/S

本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。

本软件适用于以下DEIF产品

您即将下载 1.21.1

与上一版本相比,主要更新如下:

PM compatibility: 1.35.1

Corrections

  • Corrected an issue that caused parameter #2024 Sync. dUMin to be disregarded as a lower limit for dynamic synchronisation of the voltage if #2023 Sync. dUMax was numerically smaller.
  • ATS: CB1 and CB2 can now both close in SEMI if #19122 is enabled and BTB is open.
  • Fixed issue where assigning an analogue output parameter to an already assigned analogue output would fail. Now the newly assigned parameter will have the assigned analogue output, and the parameter where the output was previously assigned will be cleared.
  • STORAGE: Corrected an issue where parameter 2664 "U ref. gain" had no effect on voltage offsets for ESS protocols SinExcel PWS1, SinExcel PWS2 30K and SinExcel 30P.
  • Corrected an issue when Modbus telegrams were split into 2 telegrams on Ethernet.
版本号 发布日期 描述

1.21.1

07/11/2024

PM compatibility: 1.35.1

Corrections

  • Corrected an issue that caused parameter #2024 Sync. dUMin to be disregarded as a lower limit for dynamic synchronisation of the voltage if #2023 Sync. dUMax was numerically smaller.
  • ATS: CB1 and CB2 can now both close in SEMI if #19122 is enabled and BTB is open.
  • Fixed issue where assigning an analogue output parameter to an already assigned analogue output would fail. Now the newly assigned parameter will have the assigned analogue output, and the parameter where the output was previously assigned will be cleared.
  • STORAGE: Corrected an issue where parameter 2664 "U ref. gain" had no effect on voltage offsets for ESS protocols SinExcel PWS1, SinExcel PWS2 30K and SinExcel 30P.
  • Corrected an issue when Modbus telegrams were split into 2 telegrams on Ethernet.

1.21.0

15/10/2024

IMPORTANT: This software requires USW-3 version 3.60.2 with PDB revision 10963 or higher.

PM compatibility: 1.35.1

New features

  • GENSET Stand Alone: Manual control of EIC speed added. Controller via digital inputs.
  • EIC: Added buzzer output for Baudouin CPCB IV.
  • EIC: Show CAN data on display and Modbus.
  • EIC: Added support of Caterpillar ADEM5.
  • BTB: BTB controllers can now be statically synchronised.
  • STORAGE: Added new BMS protocol for HuaSu Single Cluster.
  • STORAGE: Added new BCU protocol for BESS Nomad.
  • STORAGE: Added new parameter 17400 "Maintenance Charge". This allows charging based solely on maximum charge capacity from BMS instead of SOC. This feature can be used to fully charge battery systems when the SOC is not reliable.
  • STORAGE: Added new parameter 17401 "Charge capacity threshold". This sets a threshold in kW of the maximum charge capacity from the BMS when 17400 "Maintenance Charge" must adhere to stop charging.
  • STORAGE: Added new Command schedulers: 24 new schedulers that can run on specific days within a specific time period. The schedulers can now run functions such as operation modes with fixed power and reactive power setpoints and more. M-Logic command scheduler events can also be set and used.
  • STORAGE: Added new M-Logic event set to true if genset load sharing in power management system is currently in reverse power.
  • STORAGE: Added parameter set minimum genset cosphi in inductive range.
  • STORAGE: Added M-Logic lines to skip Q-Ramping for batteries.
  • STORAGE: SinExcel PWS2 30K ESS protocol now supports writing the status of ground relay for STS to open/close PE-N contactor.
  • SOLAR/STORAGE: Configurable power meter update: Offset for active and reactive power has been added.

Changes

  • The save rate of some counters has been increased.
  • GENSET: Changed MSE package protocol to always read SunSpec model 703 with an interval of 5 seconds to prevent any mismatch of feedback between AGC 150 and MSE package.
  • GENSET Stand Alone: 40 M-Logic lines now available.
  • GENSET: Nominal set 5 and 6 added in menu 6800 and 6810.
  • GENSET-MAINS: Averaged P and Q introduced in version 1.14.0 can now be used for regulation and ramping. Use menu 9268.
  • GENSET-MAINS-BTB: Averaged P, Q and S introduced in version 1.14.0 can now be used for power management. Use menu 9269.
  • EIC: Implemented Yuchai faultcodes.
  • EIC: Event log now shows SPN/FMI in display.
  • EIC: New M-Logic events and AT texts added to John Deere Stage V.
  • STORAGE: Sinosoar SP100H now stops sending internal BMS telegrams when BMS protocol configured.

Corrections

  • Fixed an issue where language write fails.
  • M-Logic commands 'Inh. start button', 'Inh. stop button', 'Inh. GB/TB button' and 'Inh. MB button' can now be read by the TDU. This requires TDU version 1.4.3.0 or later.
  • GENSET: Soft voltage recovery and I stator limitation now works regardless of the configuration of the DVC 550/D550 and DVC 350.
  • GENSET: Corrected an issue with calculating the load impact for single DGs in emulation.
  • MAINS: 'Mains power' measurement in datatracer now properly scaled based on the #9030 Scaling parameter.
  • GENSET/MAINS/BTB: Fixed issue where emulated load from ASC variants was not added correctly.
  • STORAGE: SinExcel PWS2 30K ESS protocol now supports Droop mode but only if Droop mode is set through M-Logic.
  • SOLAR/STORAGE: Fixed an issue where ESB/PVB close fail alarm did not reset even when closing ES/PV breaker was not needed.
  • SOLAR/STORAGE: Fixed an issue where M-Logic events for ESB/PVB fail alarms were never active even though the actual alarms were active and not acknowledged.

1.20.1

13/09/2024

PM compatibility: 1.35.0

Corrections:

  • ATS: Fixed an issue where BTB close inhibit could cause the CBs to become stuck in the open state when executing an AUTO operation.
  • SOLAR/STORAGE: Fixed an issue where M-Logic events for ESB/PVB fail alarms were never active even though the actual alarms were active and not acknowledged.
  • SOLAR: Fixed incorrect scaling of active and reactive power set points when writing to LIVOLTEK SunSpec PV.
  • SOLAR: Fixed an issue where the Solax MIC-G2/Pro-G2 PV protocol assumed the plant was ready to operate even though it had failed to unlock some inverters using the password.
  • ATS:Fixed issue where breaker could close automatically at blackout in application with gensets and parallel not allowed in SEMI.
  • SOLAR: Fixed an issue with Seven sensor 3S-TP and 3S-IS weather stations, where some addresses and data were missing or changed.
  • SOLAR: Fixed an issue where SunSpec Generic kept sending WMaxPct/VarMaxPct Enable even when parameter 2783 "P ref. Enable" or parameter 2784 "Q ref. Enable" was disabled.

1.20.0

15/07/2024

IMPORTANT: This software requires USW-3 version 3.60.1 with PDB revision 10688 or higher.


PM compatibility: 1.35.0

New features
   1- Added definite timer for I neutral and I earth fault. Menus 14210, 14220, 14230, and 14240.
   2- Added selection for measurement type for 4th CT trip. Menu 14200.
   3- GENSET: Added support for digital load sharing with DeepSea MSC7 in SEMI-AUTO mode.
   4- GENSET: Added three-phase current transformer inverting.
   5- EIC: Added support for Baudouin CPCB IV.
   6- SOLAR: Added new PV protocol for LIVOLTEK SunSpec.
   7- SOLAR: Added new PV protocol Eachenergy PV. Protocol also supports some Chisage PV inverters.
   8- STORAGE: Added support for Sungrow LC200 Multi PCS BCU protocol.
   9- STORAGE: Added new BMS protocol for HuaSu S06.
   10- STORAGE: Added new parameter 7960 "DEIF Generic Offset". This allows you to select between higher and lower Modbus address spaces for the ESS protocol DEIF Generic.
   11- STORAGE: Added new "Wait" status for the ESS protocol DEIF Generic. This status guarantees that the ASC controller does not send a start or stop signal over Modbus and triggers the "ESS NOT READY" status text in display.
   12- STORAGE: Added new ESS protocol for Enjoy PCS.
   13- STORAGE: Added new BMS protocol for EVE MBMU BMS.
   14- STORAGE: Added ground relay PMS application. This feature allows automatic control of the grounding point between gensets and batteries in a greenfield plant.
   15- STORAGE: Added new parameter 8152 "Gnd priority". This parameter controls whether gensets or batteries should have an active ground relay function when their nominal sizes are the same.
   16- GENSET: Added new parameter 8154 "Gnd priority". This parameter controls whether gensets or batteries should have an active ground relay function when their nominal sizes are the same.
   17- STORAGE: Updated the ESS protocol DEIF Generic to be able to write the current status of the ground relay.
   18- STORAGE: Added new ESS protocol Sungrow LC100 Utility v1.12.

Changes
   1- GENSET: Changed the stop sequence of the MSE package protocol to use a standby signal when no faults are present in AUTO mode instead of a full stop command.
   2- Text handling updated to add two more languages to the controller. This requires the new USW-3 for connection.
   3- EIC: Added M-Logic command flag to give control if preheat to Volvo EMS.
   4- EIC: Kohler KDI3404. Added support for second ECU.
   5- ATS: BTB close inhibit is aligned with BTB close failure.

Corrections
   1- STORAGE: KStar GSE 50-630 PCS protocol can handle the transition from V/f to P/Q mode.
   2- GENSET: Enter black busbar protection not working as intended in CANshare and PMS lite. This has been fixed.
   3- SOLAR/STORAGE: Corrected issue where an Open PMS plant would not automatically give an auto start signal when the operation mode was peak shaving mode and the load was above the peak shaving set point.
   4- MAINS controlled fixed for Imp/Exp with low mains breaker power caused unstable PF in GENSETs. This has been corrected.
   5- STORAGE: Corrected issue where BMS protocol Ningbo BMS would not connect/disconnect BMS racks.
   6- PMS lite: Digital output selection via display works again.
   7- Menu 9100 works correctly in marine variants.
   8- STORAGE: Fixed issue where Sinosoar SP100H was not able to read 112 registers in 1 telegram. The reactive power feedback and set point direction have also been corrected. 

1.19.0

14/05/2024

PM compatibility: 1.34.0

New features
1- Added the flexibility to move breaker feedbacks to other internal digital inputs or multi-inputs.
2- Added "Any alarm active" digital output function and M-Logic event.
3- Added controller name (not translatable) to Modbus.
4- GENSET: Added first priority as M-Logic event and configurable output.
5- GENSET: Added oil pressure alarm as configurable digital input.
6- GENSET: Added water temperature alarm as configurable digital input.
7- GENSET: Added Gen Hz/V OK delay expired to configurable output.
8- GENSET: Added current transformer scaling for support of CTs with more than one configuration.
9- MAINS: Added static synchronisation feature.
10- PMS lite: Added digital input and M-Logic command to start all available DGs.
11- ATS: Gen/Gen mode, new I/O functions and other improvements.
12- EIC: Added EIC Fan speed (SPN 986) as PID output. Added fan speed feedback (SPN 1639/975) as input to PID.
13- EIC: Added support of SDEC F20/F45.
14- EIC: Added support of Caterpillar with C7.1 AT.
15- EIC: Added support of Deutz EMR4 Stage V.
16- EIC: Added support of Cummins CM570 Industrial, CM2350 Industrial, CM2880 Industrial, Generic Industrial and PGI.
17- EIC: Enable diagnostic available from M-Logic.
18- SOLAR: Added new PV protocol for Meteocontrol Bluelog XC.
19- SOLAR: Added new M-Logic output "External ESS on PV busbar". This allows an ASC Solar to operate in Fixed Power Mode with an external battery if no other voltage source are connected to the busbar.
20- SOLAR: Added new PV protocol for Solax X3-FORTH/X3-MEGA G2.
21- SOLAR: Added new PV protocol for Solax MIC-G2/Pro-G2.
22- SOLAR: Added new PV protocol for Sineng SP320K Series.
23- STORAGE: Added support for hybrid-specific general purpose PIDs which can be used to regulate either a frequency or voltage offset on top of the normal reference.
24- STORAGE: Added a new parameter 2663 "Uf origin" config. This gives the user access to set when U and f ref. origin parameters in 2661 and 2662 are active.
25- STORAGE: Added new parameter 7086 "Inhibit MB/TB open". This allows a PCS (if supported) to delay an opening of an MB, TB or ESB if the grid mode of the PCS is not ready for the switch. This is only for semi and LTO openings, Mains failures will ignore this setting.
26- STORAGE: Added support for Lithium Valley BMS protocol.
27- STORAGE: Created parameter 15180 "Ext. DG. break. open" to set the breaker open point for ext. DGs. If the last ext. DG is required to stop in an off-grid application, the start/stop digital output is kept high until the battery has deloaded the ext. DG below the breaker open point.
28- STORAGE: Added support for Enervenue BMS protocol.
29- STORAGE: Added support for Huawei SACU Smartlogger.
30- STORAGE: Added new choice for delta alarm parameters to allow use with larger batteries.
31- STORAGE: Added support for Alfen BCU.
32- STORAGE: Added new ESS protocol for KStar GSE 50-630 PCS.
33- STORAGE: Added new BMS protocol for Gotion BMS.
34- STORAGE: Added support for BYD Cube Pro BMS.
35- STORAGE: Added new ESS protocol for Delta PCS 100HV.
36- STORAGE: Added support for Huasu S02/03 BMS.
37- STORAGE: Added parameter 8042 to allow the user to select if the PMS isochronous master functionality should also be supported in droop operation or only V/f mode.
38- STORAGE: Added support for busbar measurements to be used as inputs or set points in the general purpose PIDs.
39- STORAGE: Added parameter 2664 to allow the user to set a custom voltage reference gain compared to the nominal parameter. This is useful for adjusting the voltage for internal transformers of the PCS. 
40- STORAGE: Added new BMS protocol for BMSer Single Cluster.
41- STORAGE: Added new M-Logic line for lowest running ESS ID.
42- STORAGE: Added support for Sinosoar SP100H BCU protocol.
43- SOLAR/STORAGE: Added support for general purpose PIDs on ASC 150 with the PREMIUM option set.
44- SOLAR/STORAGE: Added support for the Acrel ADL power meter protocol.
45- SOLAR/STORAGE: Added support for hotel load. Another source drawing power from the system that is not the customer. This is subtracted from nonimal power and added to the power reference. 
46- SOLAR/STORAGE: Added new power meter protocol for Eastron Smart X96 with digital input support.
47- SOLAR/STORAGE: Added configurable power meter. With this it is possible to set up and read activer power, reactive power and up to 4 digital inputs from a power meter via user inputs in the USW.
48- SOLAR/STORAGE: Added new power meter protocol for Kohler APM403 genset meter.
49- SOLAR/STORAGE: Added support for breaker feedback for DEIF MIC-2 power meter protocol.

Changes
1- EIC: Yanmar Stage V: Regeneration request sequence now configurable through the USW. The "Regeneration needed" and "Regeneration active" icons will now display if the states are active in the ECU. The "Regeneration inhibit" command has been inverted as per the specification.
2- STORAGE: Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol to always use the VSG modes as intermediate modes, in between the required grid modes to prevent the PCS from stopping.
3- GENSET: Extended analogue load share with separate parameter for Qset as DC level at 100 % kvar. New parameter in menu 6393.
4- STORAGE: Huasu BMS update: New offset for battery current, max charge current and max discharge current. The old offset is 1600 A. The new offset is 3000 A.
5- EIC: Added additional measurements for "Engine knocking" and "Spark-ignition" to Cummins.
6- STORAGE: Updated Dynapower CPS and MPS ESS protocols to also enable the anti-islanding register if P/Q mode is forced from M-Logic.
7- GENSET/MAINS: The block fail class now also blocks the MB on sequence. It is therefore aligned with how other breakers are handled in regards to the block fail class.
8- EIC: Updated Deutz Stage V to support EPA1/2/3 and DEF low level lamp.
9- STORAGE: Changed the name of the existing Huasu BMS to Huasu S04 BMS.
10- STORAGE: Huasu S04 BMS will no longer open the DC breaker when the BMS state is fault.
11- PMS Lite: Genset on DUTY can now also be activated from M-Logic.
12- PMS Lite: Genset on DUTY now requires Auto start signal before it is able to run.
13- STORAGE: Updated SinExcel PWS1 ESS protocol to use new voltage offset and rated voltage/frequency registers based on ESS software version 1517 and later versions.
14- EIC: Updated FPT Stage V/Iveco NEF67.
15- EIC: SPN ignore - Icons are not shown if SPN/FMI combination is ignored. But it is possible to get data about the fault in the DM1 log.
16- EIC: Kohler KDI3404 - Added Pedal Input Delay events to M-Logic.
17- Digital inputs no longer shown in the USW parameter list - only visible in the I/O page.
18- GENSET: EIC and DAVR are no longer shown in the USW parameter list - only visible in ECU & DAVR page.
19- GENSET: Added new status text and info message making it more visible to the user when the GB open failure alarm is blocking a generator stop.

Corrections
1- GENSET: Q analogue load-share with Woodward SPM-D11 via IOM now works correctly.
2- SOLAR: Switch from AUTO to SEMI on another device could cause a breaker open and stop in rare cases.
3- Remote display: Unit type selection available for all software packages.
4- STORAGE: Corrected an issue where an ASC 150 Storage could not start/stop a power management plant running in island operation with start/stop parameter 8021 set to "local".
5- ATS: Open in-phase is working with 3-pos ATS breaker.
6- GENSET: P(U) droop curve deadband settings was used with a factor 10 too much. This has been corrected.
7- MAINS with Ext MB/ATS control working again. Bug introduced in version 1.13.0.
8- GENSET: Busbar frequency text was misplaced on supervision view. This has been corrected.
9- STORAGE: Corrected issue where the Megarevo MPS ESS protocol would reinitialise the start sequence of the PCS in a loop.
10- Fixed readout of CIO thermocouple set point on AGC 150 display.
11- SOLAR/STORAGE: If the voltage/frequency measurements were sourced from PV/ESS communication the phase sequence alarm would be activated. This has been corrected.
12- SOLAR: Power measurements from TCP/IP PV inverters not summarised unless RTU TX WriteType was set to broadcast. This has been corrected.
13- MAINS stand-alone with CAN bus OFF can now close MB after power cycle.
14- STORAGE: ESS auto started in OpenPMS when any external DG on BB and not when start signal was given. This has been corrected.

1.18.2

28/02/2024

PM compatibility: 1.33.0

Corrections:


• It is possible to change time from the service view menu.
• BTB deload could block a DG from executing a load-dependent stop sequence.
• SOLAR: Fixed an issue where PV protocol for Canadian CSI 3PH did not start correctly.
• STORAGE: Sync in AUTO now always work. Bug introduced in version 1.18.0.
• STORAGE: Corrected issue where multiple batteries would not share the allowed charging power when peak shaving charging limit is used.

1.18.1

09/02/2024

PM compatibility: 1.33.0

Corrections

  • STORAGE: Sungrow LC200 Powerstack. PF is now calculated based on ESS P and Q instead of S measurements.
    • STORAGE: For parameter DCdU (channel 17150), the value has been fixed when either BMS output voltage or PCS input voltage are not valid.
    • SOLAR: Corrected SMA Datamanager protocol of how NaN values are handled for P and Q. It now shows 0 kW and 0 kvar.
    • STORAGE: Corrected an issue where a failing write telegram could stop read telegrams from being sent out in the Sungrow Power stack ESS protocol.
    • STORAGE: Corrected Sungrow Powerstack ESS protocol to not send P mode and only send grid mode when stopped. This is to prevent the BESS initializing status from always showing.
    • Password 00000 is no longer valid. The lowest value is set to 00001.
    • A five-digit password is now available on the display.
    • Change of ID to Run with Run one MAINS during active LTO is now working correctly.
    • 'Auto detection' as an input for fluid pump has been removed as it was never supported. Output menu for fuel pump also removed as it is no longer used. Fuel pump, DEF pump and fluid pump outputs can now be set up for CIO 208 outputs.
    • Mains failure hysteresis was overruled in situations where no emergency sources were available. This has been fixed. Furthermore, the precision of the hysteresis calculations has been improved.
    • STORAGE/SOLAR: Corrected issue where any parameter write could reinitialise the Modbus communication if the power meter interface was set to use RTU port 1 instead of RTU port 2.

1.18.0

22/12/2023

PM compatibility: 1.33.0

New features

  • GENSET: Fuel optimisation has been updated to support applications including PV and battery.
  • GENSET: SDU available for genset land (DG).
  • TDU support added. Requires TDU version 1.4.1.0 or higher. Supports genset land, mains, BTB, solar and storage.
  • Added new M-Logic and DI input commands for simulating keyboard buttons digitally.
  • M-Logic: Added M-Logic event counters to the counters tab. This includes: No timer, timer that resets the counters, and timer that resets each individual count per counter.
  • M-Logic: Added events for detecting when a button on the display has been pushed.
  • M-Logic: Added output evaluation to Modbus.
  • Added SPN 92, 512, and 513 to PID1 input and reference (Engine drive, Engine drive marine and DG marine). The SPNs are also added to delta alarm inputs.
  • Added support for the AGC 150 DG to control a Mainspring linear generator package.
  • Added idle run interrupt via start/stop in SEMI-AUTO for genset land, genset hybrid, genset marine, genset PMS lite, engine drive and engine drive marine.
  • Added 3 new RMI custom sensors for multi-inputs.
  • Added default sensor curves in I/O configuration.
  • ATS: Extended with new features, such as support of gensets and ATS breaker (2/3 positions).
  • EIC: Added support for Iveco Stage V NEF67.
  • EIC: Added support for Cummins CM2358.
  • SOLAR/DGHYBRID: Added support for Canadian CSI 3PH
  • SOLAR: Added support for Seven Sensor 3S weather station protocol.
  • SOLAR: Added support for Seven Sensor 3S-TP GHI-Thermopile Pyranometer Weather station protocol.
  • STORAGE: Added support for HoyCore HC01CUBE BMS protocol.
  • STORAGE: Added support for Ningbo Golden Shield BMS protocol
  • STORAGE: Added support for Pixii PowerShaper ESS protocol.
  • STORAGE: Added support for Kehua BCS-B-HUD Series protocol.
  • STORAGE: Added support for Sungrow Powerstack STxxxxkWh 250kW ESS protocol
  • STORAGE: Added support for Delta EPCS 1200/1500/1725 ESS protocol.
  • STORAGE: Added support for Sungrow LC200 ESS protocol.
  • STORAGE: Added support for SinExcel 30P PCS/PDS protocol.
  • STORAGE: Added new option in the drop-down menu for the Dynapower MPS-125. The functionality of the Dynapower CPS-1500 and the Dynapower MPS-125 is the same.
  • STORAGE: Added support for Northvolt VMS ESS protocol.
  • STORAGE: Added support for a battery to act as the isochronous source in grid-forming mode together with gensets in PMS.
  • STORAGE: Added support for Huasu BMS protocol. The TCPIP port number has been updated so it is possible to change the port number on a BMS, ESS and PDS.
  • STORAGE: Added support for HagalOcean PD-003V2 BMS protocol.
  • STORAGE: Added support for Sunwoda Main BCMU protocol.
  • STORAGE: Added support for Sunwoda BCMU protocol.
  • STORAGE: Added support for KGooer BMS protocol.
  • STORAGE/SOLAR: Added support for using CAT EMCP 4 controllers directly as power meter.
  • STORAGE/SOLAR: Updated openPMS and single controller plants to support deloading of external gensets in island applications, when the start/stop digital output functionality is used.
  • STORAGE/SOLAR: PV taking maximum load. Accept PV to increase the power and stop genset, even if loads are bigger than BESS nominal size.
  • STORAGE/SOLAR: Added parameters 2671 and 2672 (P ref. const. gain & P ref. dyn. gain), which allows the user to add a local constant or dynamic gain to the power reference sent to the inverter.

Changes

  • Changed alarm list text from "Bool eval" to "Val" and values "0" / "1" to "low" / "high".
  • STORAGE: Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.
  • EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic.
  • SOLAR/DGHYBRID: Changed control registers for Power One PV protocol.
  • DG: Digital inputs 47, 48, 49 and 50 are now always visible in the I/O setup menu.
  • Option S1 controllers can now be changed to the following controller types from the display: Standalone DG, Engine drive, ATS and Remote display.
  • The shutdown override inhibit is now configurable for the following alarms: #1130 I>> 1, #3490 Emergency STOP, #4510 Overspeed 1, #4520 Overspeed 2 and #7600 EIC overspeed.
  • STORAGE: Updated the Dynapower CPS/MPS ESS protocol to always be in off-grid mode if parameter 2801 is enabled. Also added droop curve adjustments to reach requested off-grid power set points.
  • The spinning reserve stop hysteresis is now calculated based on the nominal power on busbar after next DG to stop.
  • HYBRID: Internal AC, P, Q and S power values averaged for the display and Modbus. Can be used for plant logic by selection in menu 7021.
  • EIC: Added John Deere DPF stages as M-Logic events.
  • PMS lite control between ISLAND/CanB ON and SingleDg with Mains/CanB OFF added via I/O and M-Logic.
  • PMS Lite: Added genset DUTY in AUTO.

Corrections

  • PMS priority update in 32 DG applications now working correctly.
  • Even if the DAVR controls setting was OFF, connecting to a Nidec D550 without the S4 option would generate an 'Illegal DAVR' alarm. This has been fixed.
  • The start sequence could not be cancelled between start attempts in SEMI-AUTO. This has been fixed.
  • AGC 150 Remote display experienced occasional communication loss when it was in sync screen. This has been fixed.
  • SOLAR/STORAGE: Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue.
  • SOLAR/DGHYBRID: Inverted the reactive power set point in the Sofar G3 PV protocol.
  • Using a multi-input as an external reference for regulation no longer needs a power cycle of the controller to work.
  • If a DG in PMS has an "missing all units" alarm active, it will now shutdown if its auto start signal is deactivated.
  • STORAGE: Scaling of P/Q reference and charge/discharge capacity corrected in the Matter Energy PCS protocol.
  • SOLAR/STORAGE: Fixed an issue where it was not possible to switch to application drawing 4 through Modbus Or M-Logic.
  • Peak shaving working again. Compromised in version 1.17.0.
  • Alarms with the shutdown override inhibit are now shown in the display and recorded in the alarm log if the alarm becomes active, but the fail class is still inhibited.
  • STORAGE: VSG mode changed for Sungrow LC100. Now always send, for example, F=50 and U=400, and only use P and Q set point whether the PCS is running alone or paralleling with other sources.
  • Power capacity is now requested correctly in an AMF application to start the required number of DGs and close the tie breaker (TB).
  • STORAGE: VSG updated for Sungrow LC100, LC200, Powerstack and STXXXCP-50HP: P and Q set points are used whether the PCS is running alone or paralleling with other sources.
  • STORAGE: Updated the Danfoss Vacon NXP ESS protocol, so a sync of either ESB or MB is possible.
  • SOLAR/STORAGE: Fixed scaling of the ESS AC measurements in emulation when AC scales other than 100-25000 V are used and the ESB is open.
  • Auto calculation of multi-starts with fuel optimisation is now working before the TB is closed.
  • STORAGE: Corrected the start sequence of the Sicon PCS to only send a start command once.

1.17.2

14/09/2023

PM compatibility: 1.30.1

Corrections

• SOLAR/DGHYBRID: Corrected an issue where the extended Modbus TCP/IP, would use the control ID to initialise SunSpec, instead of the monitoring ID.
• SOLAR/DGHYBRID: Fixed an issue where a multiple write telegram together with only one monitoring telegram, would only send out the monitoring telegram.
• Fixed an issue where the display LED lamps would flash faster during breaker synchronisation.
• In a LTO multi-start setup, a number of multi-start gensets did not always start to synchronise at the same time. This has been fixed. PM compatibility version raised.
• Status text 'NOT IN MAN or SEMI' no longer shown in AUTO. V0108 activated.

1.17.1

21/07/2023

PM compatibility: 1.30.0

Corrections

  • Measure viewline 5 working again.
  • Battery log is now correctly updated when the relay output of the battery test function is set to 'limits'.
  • The load shedding and adding timers were not working as a time hysteresis. This has been fixed.
  • PMS lite: The available power alarm (menu 8540) was calculated incorrectly. This has been fixed.
  • PMS lite: The ID not available alarm (menu 8511) would be activated when changing from a manually chosen ID to a different but free ID. This has been fixed.

1.17.0

30/06/2023

PM compatibility: 1.30.0

New features

  • Multi-start switch to minimum number to run right after first GB closes via configuration in menu 8360.
  • LD stop without delay available via configuration in menu 8350.
  • SOLAR/DGHYBRID: Added new Modbus TCP/IP extended setup of the ASC 150 Solar and AGC 150 DG HYRBID.
  • SOLAR/STORAGE: Added open PMS functionality.
  • SOLAR: Added support for Power One PV protocol.
  • STORAGE: Added Eastron SDM630CMT powermeter protocol.
  • Added new Modbus area for alarm list monitoring.
  • STORAGE: Added parameters 17161 and 17163. If the parameters are enabled, they will overwrite the value of the maximum charge voltage and minimum discharge voltage read from the BMS.
  • SOLAR/DGHYBRID: Added Solis logger NISE PV protocol.
  • Added option to ignore certain SPN rules from the USW.
  • DG/PMS Lite: Added supervision view-line for DG and PMS Lite.
  • SOLAR/DGHYBRID: Added Kehua SPI PV protocol.

Changes

  • SOLAR: Fixed Deye PV protocol issue.
  • STORAGE: Added max, min and avg. module temperature read-out for the Polarium BMS.
  • SOLAR: An ASC 150 SOLAR with the Premium option enabled now supports up to 32 PV inverters when using Modbus TCP/IP.
  • STORAGE: Changed the status reading of the Ausar MAE v4 ESS protocol to only cause a shutdown at critical faults and no longer minor faults.
  • STORAGE: The Ausar MAE v4 ESS protocol now supports the charging mode for low ripple current, which is turned on by the custom input to ESS in M-Logic.
  • Manual PMS priority update via digital input or M-Logic only occurs on one DG within 10 seconds.
  • SOLAR/STORAGE: Changed name of MTR protocol from MTR-3 to MTR-3/4.
  • STORAGE: RCCR inputs and outputs can now operate with negative P set points.
  • DG/PMS Lite: Updated the function list for digital outputs to include controller modes.
  • Possible to have special descriptions of specific SPN/FMI combinations for Volvo Penta EMS2 and EMS 2.4.
  • Possible to have a second ECU for Volvo Penta EMS2 and EMS 2.4.

Corrections

  • STORAGE: Fixed Yingbo Droop U/F protocol issue.
  • STORAGE: Corrected scaling issue with read current values from the GOLD BMS protocol.
  • HYBRID/SOLAR: Fixed broadcast write Modbus message for reactive power (Q) for the Matter PV protocol.

1.16.1

30/05/2023

PM compatibility: 1.29.0

Corrections:

  • EIC: Aftertreatment 1 DPF Time since Last Active Regeneration (SPN 3721) has been corrected.

1.16.0

16/05/2023

PM compatibility: 1.29.0

New features:

  • Added new device type, AGC 150 DG PMS lite.
  • EIC: Added support of Scania S8 Industrial.
  • EIC: Added support of ANGLE.
  • EIC: Added support of Jing Guan.
  • EIC: Added support of JCB 430/448 Stage V.
  • EIC: Added M-Logic outputs to inhibit DM1 protection, yellow, red and malfunction lamp alarms.
  • EIC: Added VTAs on EIC malfunction and protection alarms.
  • EIC: Added After treatment DPF Time since Last Regeneration to the display and Modbus.
  • SOLAR: Added support for Ingeteam 3Play ABS PV protocol.
  • SOLAR: Added support for Sofar -G3 PV protocol.
  • STORAGE: Added support for CATL liquid cooled BMS protocol.
  • STORAGE: Added support for Megarevo MPS protocol.
  • STORAGE: Added support for Polarium BMS protocol.
  • STORAGE: Added support for GTZKNE FX34 BMS protocol.
  • STORAGE: Added support for Yingbo PCS protocol.
  • STORAGE: Added support for Oztek OZpcs-RS40 PCS protocol.
  • STORAGE: Added support for SinExcel PWS2 30K PCS protocol.
  • STORAGE: Added Battery SOC active threshold levels in M-Logic.
  • MAINS: Added negative and zero sequence alarms.

Changes:

  • M-Logic and digital input function to allow safe regeneration.
  • Sinexcel PDS has been updated to read the power of a maximum of 8 DC strings.
  • EIC: FPT Stage V Low oil pressure alarm can only be triggered while running. Added new M-Logic event for DEF warnings.
  • EIC: Updated DM1 and DM2 headline log texts.
  • EIC: Stage V: Added the four AT regeneration states to the existing view-line.
  • EIC: Added auto acknowledge feature for engine comms alarm, channel 7570.
  • SOLAR: Changed the name of existing Ingeteam 3Play PV protocol to "Ingeteam 3Play ABI".
  • STORAGE: Changed the name of the existing CATL BMS protocol to "CATL air cooled BMS".
  • STORAGE: Changed the Atess protocol to only send start/stop commands when the run state has changed.
  • STORAGE: Changed the name of the existing SinExcel ESS protocol to "SinExcel PWS1".
  • Updated the alarm list to include alarm value, set point and fail class.
  • Added enable to the 3 inputs in the General PIDs (GPID) in the M-Logic commands.
  • Reference Set point, Min, Max and Offset added to all four General PIDs (GPIDs).
  • STORAGE: Added support for Yingbo VSG mode.

Corrections

  • Corrected issue where PV did not produce the correct Q to meet the requested grid PF, when the plant operates with a voltage-based droop and the mains voltage changes.
  • STORAGE: Fixed Jinko protocol scaling of PQ and current limits. Start/stop cmd issue also fixed.
  • DG HYBRID/STORAGE/SOLAR: When using ext. GB/ESB/PVB and MB, if the functions of the default digital inputs for GB/PVB/ESB and MB feedbacks are set to "Not used", they do not influence the breaker position feedbacks.
  • Corrected issue where service view timers froze in certain circumstances.
  • Corrected issue where output 14, output 16 and output 18 (when the device is an AGC 150 ATS) would reset after a power cycle, when the breakers (MB, GB, BTB) are continuous breakers.
  • Added active/disable feature for Easy connect in the output tab in M-Logic.
  • STORAGE: Corrected issue where in a PMS plant with PV charging enabled and the PV running with Instant P-Max enabled and set to no sensor, changing the SOC from a value less than SOC max to a value above it, would lead to the battery discharging.
  • STORAGE: Corrected issue where, when optimal DG load is enabled the battery would not charge from the PV even though the PV was not fully loaded.

1.15.1

03/04/2023

PM compatibility: 1.29.0

Corrections:

  • The breaker ext. tripped alarm is no longer triggered when reconfiguring a no breaker application to an application with a breaker.
  • STORAGE: Corrected issue where a Sinexcel PCS without VSG would switch from V/f mode to P/Q mode during ESB synchronisation resulting in sync failure.
  • MAINS: Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.
  • STORAGE/SOLAR: Using M-Logic for external PVB/ESB feedback is now possible when emulation is active.
  • Power meters in application supervision are no longer shown on external BTB.
  • Multi-input scaling issue on custom curve. It now shows the correct value compared to the curve it should follow.
  • During a transfer of ground relay, a DG that was not suited for closing its ground relay, could briefly close it and then quickly open it again. This has been fixed.
  • STORAGE/SOLAR: Incorrect handling of digital input functions, "Remote start/stop" and "Remote PVB/ESB on/off" corrected.
  • When the energy counter "kvarh" was on a viewline on the controller, the corresponding viewlines on other pages showed the last variable incorrectly. With this the costumer got the wrong information on the controller. This has been fixed.
  • DG HYBRID: PV is no longer prevented from starting in applications where no GB is configured, as long as there is voltage on the busbar.
  • DG: Fixed menu for multi-input 20 failing to display viewing of curve set points.
  • Engine Drive/Engine Drive Marine: Support of PWM output using PID1 (engine speed).
  • DVC "controls OFF" only sent few initial data after loss of communication.
  • Power ramp 1 automatic shift to power ramp 2 working correctly.

1.15.0

10/02/2023

PM compatibility: 1.29.0

New features:

  • New device type ASC 150 Solar added, supporting both single controller and PMS applications.
  • Added a pop-up before changing controller type to inform the user that everything is being reset.
  • GENSET: Added I/O setup menu for configuring internal and external I/O (CIO), including multi inputs and CIO-308 from display.
  • HYBRID: Support for SolarEdge PPC PV protocol added.
  • STORAGE: Support for DEIF MIB8000 power meter added.
  • STORAGE: Support for Eastron Smart X96 power meter added.
  • STORAGE: Support for EPC Power PCS protocol added.
  • STORAGE: Added Jinko PCS protocol.
  • STORAGE: Parameter 2810 added to the ASC-4 Battery. This can be used to configure a timeout period after the last transmitted heartbeat signal before the PCS activates an error (only for supported ESS protocols).
  • STORAGE: Parameters 2805 & 2806 have been added to support a user-adjustable offset to the droop curves used for delta frequency and delta voltage calculation when a genset or mains is connected.
  • STORAGE: When the S10 option is disabled and a user tries to change the controller type to ASC 150 storage, a pop-up is shown on the display to tell the user that the S10 option is disabled.
  • STORAGE: Added BMSer Technology BMS protocol.
  • STORAGE: Added Narada w Ctrl BMS protocol.
  • STORAGE: Support for Dynapower CPS-1500 PCS protocol added.
  • EIC: Added FPT Stage V Turbo heat protection M-Logic event.
  • EIC: Added Scania S8 safe regeneration signal M-Logic output
  • EIC: Added safe regeneration status M-Logic event.
  • EIC: Added support of Caterpillar ADEM6.
  • EIC: Updated Iveco Stage V with new alarms, M-Logic events and symbol handling.
  • EIC: Added a new view to check the status of a regeneration request from the ECU. Added new M-Logic events to Deutz EMR5 Stage V.
  • EIC: Added new view for engine icons. Added new icons for FPT Stage V.
  • STORAGE: Support for Ausar MAE version A04. ESS protocol added.
  • STORAGE: Added new M-Logic output and event to give the user the option to manually activate boost charging in supported systems.
  • STORAGE: Parameters 17201, 17202 and 17203 have been added to set a PDS spinning reserve value. This sets the percentage of the produced PDS power which should be reserved locally as extra available battery discharge capacity.
  • HYBRID: Support for using M-Logic for handling external GB, ESB and PVB added.
  • PLC-controlled PMS. When in auto mode and this mode is activated using M-Logic, a user can control the controller using a PLC (for example, digital inputs).
  • TEM analog transducer output added in menu 5750.
  • STORAGE: Added SICON PCS protocol.
  • EIC: Added support of Kohler KDI 3404 Stage V.
  • Added a new small text version of the synchroniser view.
  • STORAGE: Added support for Gold BMS protocol.

Changes:

  • HYBRID: Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the controller status.
  • Improved texts to PID regulator: Kp (Gain), Ti (Stability), Td (Derivative).
  • M-Logic event for "CBE excitation start level (rpm) reached" added.
  • M-Logic event for Load Dependent Start/Stop 2 ON/OFF status added.
  • M-Logic command for Load Dependent Start/Stop 2 ON/OFF control added.
  • Averaged P and Q (introduced in version 1.14.0) can now be used for load sharing (menu 9267).
  • STORAGE: Sungrow LC100 Utility LFP and STxxxCP50-HV ESS protocols will now use delta frequency and voltage regulation when operating in VSG on-grid mode.
  • Translations: Two languages were removed, and texts per translation (languages) were increased.
  • EIC: Added a new text on the Aftertreatment viewline when the ECU is not connected or responding.
  • EIC: Inhibit DM1 lamp alarm if engine is not running and no valid SPN is available.

Corrections:

  • STORAGE: Corrected the issue where multiple batteries operating in island with PVs make the PVs overproduce power compared to what the batteries were asked to charge.
  • The power ramp module initiates its ramp faster.
  • AGC 150 renamed text "EIC configuration" to "ECU configuration".
  • AGC 150 EIC configuration moved from GOVC to Engine subfolder in USW and display.
  • MAINS unit power measured with open MB no longer added to available power in DG.
  • Hz/V OK alarm timer (4560) no longer started in CBE, when cooldown is active, and excitation is removed.
  • STORAGE: Corrected Modbus issue with DEIF MIC 4000 power meter protocol.
  • EIC: LiveLink is now working when used with PSI.
  • STORAGE: Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.
  • Change of breaker feedback is remembered after a power cycle.
  • Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.
  • Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.
  • STORAGE: ASC 150 Storage was able to close the MB with an unsupported application alarm active.
  • Busbar emulation improved.
  • STORAGE: Corrected issue where a battery still would try to charge fully from a PV which was deloading to stop.
  • Mains failure hysteresis is now respected if one of the OK timers is running at the same time as the OK condition is reached.
  • HYBRID: It is now possible to choose P & Q measurement values from Modbus communication when in emulation.
  • Measurements P-L2, S-L1, S-L2, S-L3 readout in display scaled correctly.
  • TB remains closed even though a PV is the only power source connected to the busbar.
  • STORAGE: Corrected the calculation of frequency set point for ESB sync and MB back sync.
  • STORAGE: Corrected issue where a battery would stop in a PMS auto application if the internal mode of the ASC was set to "No dispatch" instead of only offloading when other voltage sources were connected to the busbar.

1.14.0

11/11/2022

PM compatibility: 1.27.0

New features:

  • ASC 150 Storage, now with power management support.
  • AGC 150 DG Easy connect compatibility with ASC 150 Storage.
  • Added GOV and AVR outputs to trending.
  • Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC 150.

Changes:

  • Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.
  • Configurable averaging of AC measurements for readout on display and Modbus in menu 9260.

Corrections:

  • Corrected that top viewline was flickering when external power setpoint is active. This is also present when the system is on power management.
  • BTB dividing sections sequence is now working correctly in AMF situations.
  • Corrected issue with ext comm errors always high, when rs485 port is configured as master.
  • CANShare initialisation no longer requires a power cycle to act correctly.

1.13.0

21/10/2022

PM compatibility: 1.26.0

New features:

1- New device type AGC 150 ATS added.
2- Support for DEIF DVC 350.
3- Automatic adblue refill and a generic fluid refill.
4- Automatic adblue refill: System for monitoring and start/stop filling a diesel exhaust fluid tank.
5- Fluid fill: System for monitoring and start/stop filling a fluid tank.
6- PMS mode update from ASC supported.
7- Added average for multi-input and MPU on Modbus and display.
8- New parameter #6234 GB reclose attempts added.
9- Support for M-Logic shortcuts via shortcut menu.
10- Five new LED lamp view lines.
11- Added shortcut for engine regeneration.
12- Added shortcut for ECU diagnose.
13- Virtual event toggles when using Modbus. Created new virtual switch event that stays high when put high in Modbus and M-Logic.
14- EIC: Added support of Jichai JC15T JG protocol.
15- EIC: Added support of Cummins CM2850.
16- EIC: Added support of Cummins CM2350.
17- EIC: Added support of Cummins CM2880.
18- EIC: Added support of Weichai E6.
19- HYBRID: Support for INVT XG series PV protocol added.
20- HYBRID: Support for Matter Energy PV protocol added.
21- HYBRID: Support for external MB operation added to DG HYBRID (option S1) and ASC 150 added. Ext. MB feedback can also now be set through M-Logic.

Changes:

1- The low speed digital input and idle start/stop timers can now be used together.
2- Tier 4 icons view now display a frame where icons will be shown.
3- Changed overload alarm 5 (1490) to low load alarm.
4- In CANshare mode, ID and total number of gensets now shown on lower tiny line in measure views.
5- The default application configuration name has been updated.
6- Gov renamed to speed control in menu structure.
7- Common names in digital inputs (from 1.12.0) used in menu system on display.

Corrections:

1- PID force min/max is now working when offset is used.

1.12.1

30/09/2022

PM compatibility: 1.25.0

Corrections:

  • Modbus broadcast telegrams now works again when communicating with multiple PV inverters on the DGHYBRID controller.
  • Corrected issue where an external Modbus RTU master sending telegrams into a RTU port also configured as a master on the AGC150 DGHYBRID controller could cause a restart.
  • Corrected the Modbus addresses used for P/Q ref. and ACP/ACQ reading for the SMA Data Manager PV protocol.

1.12.0

12/09/2022

PM compatibility: 1.25.0

New features:

  • New device type ASC 150 Storage added.
  • External controlled MB available on stand-alone (option S1) generator variants (LAND, MARINE, HYBRID).
  • CAN B protocol changed with M-Logic to PM and CanShare.
  • Oneshot logic in M-Logic.
  • Current alarms for 4th CT measurement added. Menu 7420 and 7430.
  • CBE re-run failure alarm added. Menu 2230.
  • Text tree structure in USW translation added.
  • List with common names for digital inputs.
  • EIC: Added FPT Stage V SPN/FMI fault codes.
  • EIC: Added support of KWG ISO5 isolation monitor.
  • EIC: Added support of QiYao Gas.
  • EIC: Added support of Doosan stage V protocol.
  • HYBRID: Added support for Thea PV protocol.
  • HYBRID: Added support for Deye SUN 30-50K-G03 PV protocol (Unicast only).

Changes:

  • I/O status added to trending in USW.
  • Busbar block handling in PMS now allowed to let the system (DG, MAINS etc) run even though any breaker has position failure.
  • EIC: Scania S8 is now showing regeneration active symbol when manual regeneration is active.
  • Reduced number of languages to 10.

Corrections:

  • #7804 DAVR bias range now works correctly for DVC 550 and D550 DAVRs.
  • Update of modes on all controllers in a PMS application has been made more robust.
  • PMS island load sharing would not work correctly when #9030 Scaling was set to something other than default. This has been corrected. PMS asymmetrical load sharing in island also corrected when using a different scaling than default.
  • In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.
  • Diagnostics timer (#6701) is now working.
  • Channel numbers 7720+7730+7731 in USW aligned with channel numbers in display, so all is 7721+7731+7732 to avoid confusion.
  • CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.
  • Static synchronising works in 3W3 coupling.
  • Shutdown override did not work correctly when the failclass of an alarm was set to GB trip, GB trip + stop or shutdown. This has been fixed.

1.11.0

11/07/2022

PM compatibility: 1.25.0

New features:

  • JC15D Weifu alarm texts added to DM1 log.
  • Added support of JC15D WYS EIC protocol.
  • Added support of JC190 EIC protocol.
  • Added support of Bosch EDC17CV54TMTL EIC protocol.
  • Added configurable TSC1 transmission rate and checksum/counter for Generic J1939.
  • Added support of Xichai EIC protocol.
  • Enable/disable alarm ack. via J1939 (DM11).
  • Added support of Kubota EIC protocol.
  • Extended RMI 20 Points in multi-inputs.
  • Extended mA 17 Points in multi-inputs.
  • Hybrid Supervision view on controller display added.
  • Parameter to block nominal settings changed.
  • Extended EIC wait to start (preheat) support. Introduced M-Logic command to inhibit wait to start.
  • View line: Added kW per phase (L1, L2, L3).
  • View line: Added kW per phase in percent (L1, L2, L3).
  • View line: Added Power factor per phase (L1, L2, L3).
  • EIC: Added support of Scania EMS2 S8 HC Evaporation Status in M-logic and view.
  • View line: Added Charge Alternator Voltage - D plus voltage.
  • Automatic speed detection view line.
  • Automatic oil pressure view line.
  • Automatic water temperature view line.
  • Automatic fuel level detection view line.
  • Multi-input view lines change text with RMI selected.
  • Added RMI Custom to multi-input input type.

Changes:

  • J1939 protocol "Jichai" renamed to "JC15D Weifu".
  • FPT/Iveco Stage V updated.
  • Default views updated.
  • Default values for multi-input.

Corrections:

  • N + X ON/OFF via digital input or M-Logic corrected.
  • Busbar measurement working correct in single and split phase with BB set to 3W3.
  • A genset will now charge a battery with the correct amount during negative PMS set points.
  • A genset will now calculate the correct power reference if a battery operating as a energy source is charging from excess PV power.
  • A running DG with its GB closed could react to invalid power management data when changing from a single DG application to a standard application.
  • DVC 550/D550: Stator current limitation events in M-Logic did not work.
  • A mains could issue a start signal to DGs based on invalid power management data when a BTB was power cycled.
  • AOP-2 button emulation from USW-3 working.
  • Fault in PDB. Alarm Relay ND and NE text swap. I/O setup is wrong; parameter is correct.
  • External generator breaker configuration on DGs corrected so GB relays are configurable.
  • Configuration of running detection timer is now working from display.

1.10.4

30/06/2022

PM compatibility: 1.25.0

Corrections:

  • Corrected an issue where two or more DGs could end up with the same priority.

1.10.3

01/06/2022

PM compatibility: 1.25.0

Corrections:

  • Engine Drive Marine, Marine DG ISLAND: Remote Start and Remote Stop working.
  • MARINE: Status text updates.
  • MARINE: TEST function now stops the engine when TEST is finalised.
  • MARINE: Idle run stops engine correct when using Low speed or timer.

1.10.2

19/04/2022

PM compatibility: 1.25.0

Corrections:

  • GOV output was sometimes raising to 100% when GB was closed with static sync. This has been fixed.
  • Deutz EMR Stage V stop telegram corrected.

1.10.1

18/03/2022

PM compatibility: 1.25.0

Corrections:

  • EIC autoviews is not deleted doing power up.
  • EIC Deutz EMR Stage V: DEF level is shown and SPN5246 is mapped to m-logic eic derate active.
  • MARINE EDG: GB stays closed in SEMI mode even though the STOP button is pressed.
  • Translation issue seen when loading multiple languages is corrected.

1.10.0

28/02/2022

PM compatibility: 1.25.0

New features:

  • Controller types 'Genset Marine' and 'Engine Drive Marine' added.
  • DG HYBRID: Growatt CP100-CP250 & Growatt CP500-CP2250 PV protocols added.
  • DG HYBRID: Growatt Mac, Max & Mid series PV protocol added.
  • RMI Water temperature extended ranges.
  • DG HYBRID: SMA Data Manager PV protocol added.
  • Support of Perkins Stage V 120xJ (SU, VM) EIC protocol added.
  • Support of Deutz EMR5 Stage V EIC protocol added.
  • Activate/deactivate spinning reserve via M-Logic added.

Changes:

  • DG HYBRID: Renamed "Growatt" PV protocol to "Growatt UE-series".

Corrections:

  • DG HYBRID: Q share and DG cosphi limits now works correctly compared to the cosphi of the DG.
  • Increased measurement inaccuracy at changing frequency could be seen infrequently.
  • AMF Overlap is now working when modeshift is used with two or more MAINS units in power management.
  • Numbers of view pages is updated correctly.

1.09.1

08/02/2022

PM compatibility: 1.24.2

Corrections:

  • Logs stored correctly to work after a power cycle.

1.09.0

14/12/2021

PM compatibility: 1.24.2

New features:

  • DG HYBRID: Added GoodWe HT Series PV protocol.
  • DG HYBRID: Huawei V.3 PV protocol added. This protocol replaces all older Huawei protocols for newer inverter firmware versions.
  • M-Logic input events for auto start command from any DG, any MAINS or any BATTERY in Plant.
  • RPM based on calculation from the AC frequency reading.
  • DG HYBRID: Added Havells 1-40kw PV protocol.
  • DG HYBRID: Added Havells 50-70kw PV protocol.
  • DG HYBRID: Added Sofar Solar 1-40kw PV protocol.
  • DG HYBRID: Added Sofar Solar 50-70kw PV protocol.
  • DG HYBRID: Added Chint (CPS) Boost 100-250kW PV protocol.
  • M-Logic command for turning display backlight and all LEDs OFF added.

Changes:

  • PM-id added to lower info line together with page-number and PM-prio.
  • Multi-input wire-break setup: Delay, Auto acknowledge and Inhibit added.

Corrections:

  • No ASC-4 PV irradiance sensor could make AGC DG's provide inadequate power for mains power export.
  • Cosphi superior set points now work with only PV or Battery units on the busbar together with a AGC 150 mains.
  • EIC and CIO communication can run at the same time again.

1.08.1

01/12/2021

PM compatibility: 1.24.2

Corrections:

  • Minimum load was not respected when using droop curve 1.
  • 'Guided view with genset' now shows start/stop buttons equal on all DG's in an ISLAND PMS setup.
  • DG HYBRID: Added correct scaling for P/Q reference and changed the Broadcast ID to be 0xFF in the Polycab 50-60kW PV protocol.
  • EIC generic J1939: Missing data readings (SPN 1119 and 1180) added to protocol.

1.08.0

11/11/2021

PM compatibility: 1.24.2

New features:

  • PMS redundancy via Ethernet added.
  • DG HYBRID: Added Modbus TCP/IP master communication support for PV and weather Modbus interfaces.
  • DG HYBRID: New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Added support of Cummins KTA19 EIC protocol.
  • Added electrical load telegram to Caterpillar engine I/F.
  • DG HYBRID: Havells 80-136kW PV protocol added.
  • DG HYBRID: Polycab 50-60kW PV protocol added.
  • DG HYBRID: FIMER PVS980 PV protocol added.
  • Power ramp improved.
  • Added support of Jichai EIC protocol.
  • Added supported ECU types.
  • Added Preheat functionality for Perkins Stage V.
  • NTP Support added.

Changes:

  • Maximum timer extended to 3200.0 s on a number of protections (AC, digital inputs, MPU, EIC).

Corrections:

  • QSPI communication speed corrected.
  • Self-check error 49 during read of log.
  • DG HYBRID: EVVO PV active power control corrected.
  • ISLAND deload of last GB now works as expected, so the GB opens when the frequency has dropped 0.5 Hz below nominal.
  • Deload TB before GB opens function works correctly in PEAK SHAVING.
  • FULL TEST available again. Was taken out in 1.04.2.
  • DG HYBRID: POA and other weather-station values can now be written with DEIF OPEN communication.
  • Analogue output limits for transducer output corrected, so min/max on input is reflected directly to output limits.
  • PMS priority change via M-Logic or Modbus now works correctly.
  • Fast OverCurrent max set point reduced from 350 % to 300 % due to alignment with data sheet. Backward compatibility compromised.
  • If the ground relay was enabled and the application configuration was a non-PMS single DG, the GB would not open when deloaded.
  • df/dt now operates on the mains side measurements.
  • Configuration of outputs 15-18 is now correct after power cycle.
  • Alarm texts are shown when the alarm is reviewed from CAT EMCP.

1.07.0

21/06/2021

PM compatibility: 1.24.1.

New features:

  • Multiple busbars on CANshare is implemented, and 64 BTBs are available.
  • Remote display functionality is added. This includes a new controller type.
  • Reverse power: 3 AC protections are added.
  • Support of Perkins Stage V EIC protocol is added.

Changes:

  • MAINS connection are now allowed in the STAND ALONE variant and none GB or external GB.
  • DG HYBRID: PV semi start/stop commands are added to M-Logic and to the Modbus commands.
  • Weichai gas EIC protocol is updated with new data readings.

Corrections:

  • "Fuel optimization" and "Fuel optimization + running hours" are now working with percent values.
  • EIC transmission rate stability is improved.
  • DG HYBRID: It is no longer possible for the unit to send negative P-ref set points to a PV inverter.
  • Power emulation for AGC 150 with Option S1 is now calculated and shown correctly.
  • DG HYBRID: Corrected an issue where Emulation PV was not able to start with PV protocol set to OFF.
  • DG HYBRID: Corrected an issue where Goodwe DT and MT protocols would show negative ACP at values above 32768 W.

1.06.1

06/05/2021

Version 1.06.1 based on 1.06.0.

PM compatibility: 1.23.0.

Corrections:

  • Limit events is added in M-Logic for Extended M-Logic Alarms.
  • DVC 550/D550 now works with the EIC protocol Volvo Penta EMS 2.4.

1.06.0

29/04/2021

PM compatibility: 1.23.0.

New features:

  • DG HYBRID: Added new parameter #17132 "Curtail threshold".
  • Added support for John Deere Stage V EIC protocol.
  • Added support for Isuzu EIC protocol.
  • Added new parameter #6176 "Not running delay". Can be used as a hysteresis if the running feedback unexpectedly falls under the running detection level.
  • Added support for Kohler EIC protocol.
  • Added support for FPT + Iveco Stage V EIC protocol.
  • Added four new M-Logic alarms with extended delay in menu 3620-3650.
  • Added Event log entry when the application setup changes.
  • DG HYBRID: Added monitoring tool for Modbus master communication within the service view under communication analysis.
  • Added new GOV and AVR step test in parameter group #2970.
  • DG HYBRID: Added support for Sungrow Logger 1000 PV protocol.
  • DG HYBRID: Added support for Growatt PV protocol.
  • Added keyswitch for Diesel engine.
  • Added new controller type 'Engine Drive'.
    • Added MPU and EIC speed as PID1 input.
    • Added EIC as PID1 output.
    • Added digital input functions to control PID1 output (Semi manual mode).
    • Added ramp functionality for PID1.
    • Added new shortcut menu (Engine shortcuts).
  • DG HYBRID: Added support of PV breaker.
  • EIC speed (SPN 190) and MPU speed added to delta alarms.

Changes:

  • Default views for DG are changed.
  • Engine I/F list is reorganized in alphabetical order.
  • Fuel pump logic is available for Stand-alone and Core software versions.
  • The SunSpec identifying information shown in the display is improved.
  • PV protocols are listed in alphabetic order in the display and the USW.
  • DG HYBRID: Added fallback timer for power limit on SunSpec (Parameter 17180).
  • Minimum timer for AC busbar alarms is decreased from 0.1 to 0.04 seconds.
  • Text is changed in the shortcut menu.
  • Engine emission system failure Tier4 icon now follows FMI levels and SPN3349 set to 7 for protocols with 10 ms transmission rate.

Corrections:

  • Menu 6231 for GB close delay is no longer available when the application is power management.
  • Corrected that strange texts sometimes were shown in the USW log.
  • "L-L and P total" view now shows the correct value.
  • Power factor set point on Modbus is now correctly initialized after power-up.
  • General improvements to the D550/DVC 550 integration module.
  • Ph-ph voltage will not saturate before the hardware limit is reached.
  • Correct behavior of dfdt is now ensured when the number of periods are set above 12.
  • The variable needed for angle check in Q dep U< alarm is updated.

1.05.4

06/04/2021

PM compatibility: 1.22.0.

Corrections:

  • HYBRID: When reconfiguration of the RS-485 ports, power cycle of the unit is no longer needed.
  • HYBRID: The unit is now able to automatically switch between Sunspec addresses (40000, 50000 and 0). If Sunspec initialization is not compatible, reinitialization starts in 20 seconds.

1.05.3

02/03/2021

PM compatibility: 1.22.0.

Corrections:

  • Secured mode now works when Fuel optimisation is in use.
  • Priority update now works when more than 16 gensets or more than 16 mains are present in a plant configuration.
  • PMS priority data is properly maintained internally in all genset controllers.
  • When digital input 50 is not used as feedback, it is no longer disturbing the check of breaker status.
  • Breaker feedbacks are properly updated on the I/O status and the I/O setup page.

1.05.2

06/01/2021

PM compatibility: 1.22.0.

Corrections:

  •  Support is added for Volvo engine with 60 Hz as primary speed when Volvo proprietary engine speed is used.
  •  Generator under-frequency and under-voltage alarms are now inhibited during idle run.

1.05.1

08/12/2020

PM compatibility: 1.22.0.

Corrections:

  •  AGC 150 Hybrid controller got stuck in Sunspec initialize, due to a previously unknown Modbus model in the ABB PVS175 PV inverter.
  •  Transmitting DVC 550/D550 parameters over the CAN was irregular. This is corrected.

1-05-0

30/11/2020

PM compatibility: 1.22.0.

New features:

  • Support for the new input configuration interface.
  • DVC 550 PT100 measurements in display and selection in delta alarms.
  • EIC start/stop as a parameter.
  • M-Logic to start DG and close/inhibit close GB in auto mode. M-Logic to inhibit TB close.
  • Scania EMS2 S8 Engine I/F.
  • Configurable spinning reserve request using parameter 8930, not supported in BTB applications.
  • Ground breaker to CORE package
  • Shutdown override as new inhibit.
  • Parameter to use nominal frequency or rpm as reference for EIC speed offset.
  • Support for Volvo Penta EMS2.4.
  • New combined views with electrical data.

Changes:

  • Configurable multi inputs and new DM1 telegrams for JCB LiveLink. 
  • Racked out breaker On/off displayed in log.
  • Minimum level of "Frequency detection level (6165)" changed from 20hz to 10hz. 

Corrections:

  • Ground relay routine improved:
          - There is now always an overlap when transferring ground relays between DGs.
          - The best DG to hold the ground relay now keeps it closed during de-load and transfer of the ground relay happens when the de-loading DG is ready to open its GB.
          - Older versions with ground relay enabled are no longer compatible going forward.
  • AGC 150 Read log freezes controller. 
  • Phase calculations are now properly performed and transmitted to the DVC 550 & D550 when changed through M-Logic.
  • AC configuration in the D550/DVC 550 is now controlled by the AGC.
  • When configured for split phase operation, the nominal voltage setpoint is now correctly calculated for the DVC 550/D550.
  • New parameter #7746 DAVR AC config is introduced. This helps fix situations where the DAVR is not able to follow the AC configuration of the AGC.
  • Configuring a mains standalone application with the CAN bus set to OFF in the application configuration prevented the MB from closing. This has been corrected.
  • If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open. This has been corrected.
  • Alternative engine speed control for Volvo protocols including counter and checksum is added. Can be enabled with the new parameter 15110.
  • LTO now works correctly when unit is STAND-ALONE (non-sync).
  • Multi input alarm level 2 Min/Max now updates correctly when output limits are changed from multi input configuration in USW.

1-04-2

22/09/2020

PM compatibility: 1.17.2.

Corrections:

  •    TEST type in StandAlone (option S1) is limited to SIMPLE TEST.
  •    Limit evaluation of multi-input 23 alarm for use in M-Logic is now working.
  •    Included CAN Start/Stop in the Hatz proprietary CM1 telegram.
  •    Current handling of TIER 4 icons for the Hatz protocol.
  •    Read Aftertreatment 1 Intake Gas telegram for the Hatz protocol.
  •    Necessary to force a regeneration until current feedback is received from ECU.
  •    Fuel optimization + running hours does not swap DG's at fixed load.

1-04-1

29/07/2020

Version 1.04.1 based on 1.04.0

PM compatibility: 1.17.2

Corrections:

  • Errors regarding powermanagement applications with PV, ASC and battery controller corrected.

1.03.1

14/05/2020

PM compatibility: 1.17.2.

Corrections:

  • Analog output limits for the transducer output are corrected.
  • Transducer input range is extended on multi inputs to support the setup of limits corrected in #1.
  • STOP button has always a lid on the genset when running German rule, V0108.

1.03.0

03/04/2020

PM compatibility: 1.17.2

New features:

  •    DVC 550 and D550 are now supported by the AGC.
  •    Configurable amount of units for triggering Fatal CAN Error alarm, added in menu 8800.

Changes:

  •    Emulated value for I>> alarms added.
  •    Easy Connect is no longer blocking DG start in single DG applications.

Corrections:

  •    In AMF situations where the mains had no TB, and #7065 mains fail ctrl was set to "Start engine" and the DGs had to connect through a BTB to supply the mains, the MB would not open as it did not have information about whether or not the DGs Hz/V OK timer had run out. And as the MB would not open the BTB would not close resulting in a deadlock. This has been corrected.
  •    TB power capacity overrule timer will now run if there is an active MB trip failclass or the MB cannot be closed.
  •    Ring bus applications: If BTBs were closed at and under application configuration, opening a BTB could cause a DG to start without a proper start signal.
  •    Fixed a situation where opening a semi BTB, in a plant with an active start signal, would cause a DG to briefly engange its start prepare relay.
  •    In a plant where all DGs are divided by open BTBs, if for example, DG1 is running and needs help from DG2, DG2 would start and close its breaker, then synchronize the BTB, and as the BTB would close, DG3 would briefly engange its start prepare relay. This has been fixed.
  •    PMS + ISLAND + SEMI + GUIDED MIMIC: Start/stop buttons LED visible when relevant on genset.

1.02.0

26/03/2020

PM compatibility: 1.17.0.

New features:

  •    Two new EIC aftertreatment alarms have been added: "High SOOT warning" and "High SOOT shutdown".

Changes:

  •    Vector jump, df/dt, positive busbar sequence and directional over-current are now available in CORE MAINS and CORE BTB.
  •    New TIER 4 icons for JCB EIC are added.

Corrections:

  •    Parameter handling could in special cases cause decimals to be handled incorrectly in the display menu. This is corrected.
  •    Problems with freeze and white screen are now prevented.
  •    Analogue values from CIO 308 are now shown correctly in view-lines.
  •    JUMP menu causing unwanted parameter change is corrected.
  •    JUMP menu freeze is now prevented.
  •    Overspeed 2 menu (4520) is now shown correctly.
  •    GUIDED mimic is corrected with external breaker, so GB ON/OFF buttons do not lit up.

1.01.0

19/12/2019

PM compatibility: 1.17.0.

New features:

  • EIC: JCB J1939 protocol is added.
  • EIC: DEF level shown on lower tiny line in measure views. 
  • Stand Alone (option S1) is implemented. Breaker selection is extended with 'No breaker' and 'External breaker'.
  • LED colors can now be changed. An option to select a different LED color behavior in parameter 6084.
  • Now it is possible to change the source address for PGN GC1 and CM1 independently of each other for all engine protocols.

Corrections:

  • BTB can now be part of a plant with CORE units.

1.00.3

22/10/2019

PM compatibility: 1.17.0

Corrections:

  • External BTB position feedbacks are now working again.
  • Phase sequence error alarms are now working 3W3 coupling.
  • Service timers can now be reset.
  • Translated texts for I/O texts in Service View are now shown correctly.

1.00.2

05/08/2019

Version 1.00.2 based on 1.00.1

PM compatibility: 1.17.0

Corrections:

  •    Deloading the TB is now properly handled in test mode when parameter #8273 "Deload TB back sync." is enabled
  •    Multi inputs could go into overflow when set to voltage type
  •    Internal analog outputs (52/55) now works correct when used with GP PID.
  •    Genset priority would update even though the user had not issued an update.
  •    If mains ATS is active, and TB is closed onto a healthy busbar, and the controller is powercycled, the TB no longer opens and closes on power up.
  •    When sending a stop command during idle start the idle relay is kept closed.
  •    Fixed situations where multi start would not work correctly in ISLAND and AMF applications.
  •    M-Logic flag "Run all available island DG's" starts all DG's when activated.
  •    Mimic for BTB and MAINS with External breaker updated, so the respective buttons (open/close) are not visible.
  •    Various parameters added to parameter tree
  •    Improved Easy Connect functionality:
          - Rapid menu changes prevented
          - Info text on removed units
          - Possibility to remove the other unit with pop-up when only 2 in plant
          - Better handling of fault situations (Appl. hazard or Duplicate CAN ID)
          - Removed units are no longer blocked from running
          - Faster indication of changes on the other units

1.00.0

30/04/2019

PM compatibility: 1.17.0

  • Initial release

在此页面,您可以下载产品的更新软件,并使用各种实用工具和附加组件设置、检测故障和配置产品。

请注意,用户无法更新我们的所有产品。同时也不是所有产品都配有实用工具。因此,本页的软件列表不能视为DEIF产品的概述。

DEIF将登记您注册的下载邮箱地址,以便在未来需要时发送有关的更新信息。

DEIF不对产品更新失败或使用实用工具造成的任何后果负责。DEIF A/S也不对软件升级导致的产品行为变化的后果负责。用户始终有责任在调试前确保正确的设置和配置。请在更新产品之前查阅软件的更新日志。

www.deif.cn软件下载许可协议

下载的软件仍是DEIF的财产。本软件不得用于商业目的分发, 不得全部或部分更改或重复使用,也不得出售给任何第三方。

最新版本,功能齐全

我们始终建议您安装最新版本的软件,以充分利用您的DEIF产品。

所有更新的软件都可以从www.deif.cn->支持->下载->软件栏目下下载。

如果您在查找产品的相关软件时有任何疑问或问题,请随时致电丹控电气(上海)有限公司,电话: +86 21 68796200,或者发送电子邮件至support@deif.cn, 我们随时为您服务。